European Journal of Radiology
Volume 54, Issue 3 , Pages 344-351 , June 2005

Interrater reliability of sonographic examinations of orbital fractures

  • Jank Siegfried

      Affiliations

    • Department of Oral and Maxillofacial Surgery, University of Innsbruck, Maximilianstr. 10, A-6020 Innsbruck, Australia
    • Corresponding Author InformationCorresponding author. Tel.: +43 512 504 24390, +43 699 11107628 (M).
  • ,
  • Deibl Martina

      Affiliations

    • Department of Biostatistics, University of Innsbruck, Austria
  • ,
  • Strobl Heinrich

      Affiliations

    • Department of Oral and Maxillofacial Surgery, University of Innsbruck, Maximilianstr. 10, A-6020 Innsbruck, Australia
  • ,
  • Oberrauch Andreas

      Affiliations

    • Department of Oral and Maxillofacial Surgery, University of Innsbruck, Maximilianstr. 10, A-6020 Innsbruck, Australia
  • ,
  • Nicasi Alessandro

      Affiliations

    • Department of Oral and Maxillofacial Surgery, University of Innsbruck, Maximilianstr. 10, A-6020 Innsbruck, Australia
  • ,
  • Missmann Martin

      Affiliations

    • Department of Oral and Maxillofacial Surgery, University of Innsbruck, Maximilianstr. 10, A-6020 Innsbruck, Australia
  • ,
  • Bodner Gerd

      Affiliations

    • Department of Radiology, University of Innsbruck, Austria

Received 7 June 2004 ,Revised 12 June 2004 ,Accepted 14 July 2004.

References 

  1. Ball JB. Direct oblique sagittal CT of orbital wall fractures. AJR Am. J. Roentgenol. 1987;148:601–608
  2. Benateau H, Chevalier E, Hamon M, et al. The three dimensiononal spiral scanner and volume rendering technique: importance in craniofacial traumatology and reconstructive surgery. Rev. Stomatol. Chir. Maxillofac. 2002;103:233–238
  3. Daly BD, Russell JL, Davidson MJ, Lamb JT. Thin section computed tomography in the evaluation of nasoethmoidal trauma. Clin. Radiol. 1990;41:272–275
  4. Imhof H, Czerny C, Dirisamer A. Head and neck imaging with MDCT. Eur. J. Radiol. 2003;45:23–31
  5. Berado N, Leban SG, Williams FA. A comparison of radiographic treatment for evaluation of the orbit. J. Oral. Maxillofac. Surg. 1998;46:844–849
  6. Dorbisz H, Voegeli E, Hardt N. Conventional radiology and computed tomography in facial fractures. Rontgenblatter. 1993;36:428–433
  7. Iinuma T, Ishio K, Yoshinami H, Kuriyama J, Hirota Y. Orbital wall fractures: a comparison of computed tomography and conventional views. Nippon Jibiinkoka Kaiho. 1993;96:175–181
  8. Forrest CR, Lata AC, Marcuzzi DW, Bailey MH. The role of orbital ultrasound in the diagnosis of orbital fractures. Plast. Reconstr Surg. 1993;92:28–34
  9. Jenkins CM, Thuau H. Ultrasound imaging assessment of fractures of the orbital floor. Clin. Radiol. 1997;52:708–711
  10. Klinger M, Danter J, Siegert R. Ultrasound diagnosis of orbital floor fractures: an alternative to computerized tomography. Laringorhinootologie. 1996;75:242–244
  11. Lata AC, Marcuzzi DW, Forrest CR. Comparison of real-time ultrasonography and coronal computed tomography in the diagnosis of orbital fractures. Can. Assoc. Radiol. J. 1993;44:371–376
  12. McCann PJ, Brocklebank LM, Ayoub AF. Assessment of zygomatico-orbital complex fractures using ultrasonography. Br. J. Oral. Maxillofac. Surg. 2000;38:525–529
  13. Takashi H, Manders E, Nagamoto K, Saggers G. Ultrasonic observation of facial bone fractures. J. Oral. Maxillofac. Surg. 1996;54:776–778
  14. Jank S, Strobl H, Emshoff R, et al. Bildgebende Diagnostik von medialen und lateralen Orbitawandfrakturen. Ultraschall versus CT. Mund Kiefer Gesichtschir. 2003;4:208–213
  15. Jank S, Emshoff R, Etzelsdorfer M, Strobl H, Nicasi A, Norer B. Effectiveness of ultrasonography in determining medial and lateral orbital wall fractures with a curved array transducer. J. Oral. Maxillofac. Surg. 2004;62:451–455
  16. Jank S, Emshoff R, Etzelsdorfer M, Strobl H, Nicasi A, Norer B. The diagnostic value of ultrasonography in the detection of orbital floor fractures with a curved array transducer. Int. J. Oral. Maxillofac. Surg. 2004;33:13–18
  17. Jank S, Emshoff R, Etzelsdorfer M, Strobl H, Nicasi A, Norer B. Ultrasound versus computed tomography in the imaging of orbital floor fractures. J. Oral. Maxillofac. Surg. 2004;62:150–154
  18. Fleiss J. Reliability of measurements. The Design and Analysis of Clinical Experiments. New York: John Wiley & Sons; 1986;
  19. Jank S, Schuchter B, Strobl H, et al. Post-traumatic ocular motility in orbital floor fractures. Mund Kiefer Gesichtschir. 2003;7:19–24
  20. Jank S, Schuchter B, Emshoff R, et al. Clinical signs of orbital wall fractures as a function of anatomic location. Oral. Surg. Oral. Med. Oral. Pathol. Oral. Radiol. Endod. 2003;96:149–153

PII: S0720-048X(04)00265-7

doi: 10.1016/j.ejrad.2004.07.009

European Journal of Radiology
Volume 54, Issue 3 , Pages 344-351 , June 2005