Volume 53, Issue 1 , Pages 84-89 , January 2005

Visualization of femorotibial contact in total knee arthroplasty using X-ray fluoroscopy

  • Takaharu Yamazaki

      Affiliations

    • Department of Medical Robotics and Image Sciences, Osaka University, Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka 565-0871, Japan
    • Corresponding Author InformationCorresponding author. Tel.: +81-6-6879-3564; fax: +81-6-6879-3569.
  • ,
  • Tetsu Watanabe

      Affiliations

    • Department of Orthopaedics, Osaka University, Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka 565-0871, Japan
  • ,
  • Yoshikazu Nakajima

      Affiliations

    • Department of Medical Robotics and Image Sciences, Osaka University, Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka 565-0871, Japan
  • ,
  • Kazuomi Sugamoto

      Affiliations

    • Department of Orthopaedics, Osaka University, Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka 565-0871, Japan
  • ,
  • Tetsuya Tomita

      Affiliations

    • Department of Orthopaedics, Osaka University, Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka 565-0871, Japan
  • ,
  • Daisuke Maeda

      Affiliations

    • Department of Radiology, Osaka University Hospital, 2-2 Yamadaoka, Suita, Osaka 565-0871, Japan
  • ,
  • Wataru Sahara

      Affiliations

    • Department of Orthopaedics, Osaka University, Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka 565-0871, Japan
  • ,
  • Hideki Yoshikawa

      Affiliations

    • Department of Orthopaedics, Osaka University, Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka 565-0871, Japan
  • ,
  • Shinichi Tamura

      Affiliations

    • Department of Medical Robotics and Image Sciences, Osaka University, Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka 565-0871, Japan

Received 15 September 2003 ,Accepted 17 November 2003.

References 

  1. Bartel DL, Bickness VL, Wright TM. The effect of conformity, thickness, and material stresses in UHMWPE components for total joint replacement. J. Bone Joint Surg. 1989;68(A):1041–1051
  2. Wright TM, Rimnac CM, Stulberg SD. Wear of polyethylene in total joint replacement. Observations from retrieved PCA knee implants. Clin. Orthop. 1992;276:126–134
  3. Morra EA, Postak PD, Plaxton NA, Greenwald AS. The effects of external torque on polyethylene tibial insert damage patterns. Clin. Orthop. 2003;410:90–100
  4. Szivek JA, Anderson PL, Benjamin JB. Average and peak contact stress distribution evaluation of total knee arthroplasties. J. Arthroplasty. 1996;11:952–963
  5. Harris ML, Morberg P, Bruce WJM, Walsh WR. An improved method for measuring tibiofemoral contact areas in total knee arthroplasty: a comparison of k-scan sensor and fuji film. J. Biomech. 1999;32:951–958
  6. Banks SA, Hodge WA. Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy. IEEE Trans. Biomed. Eng. 1996;43:638–649
  7. Hoff WA, Komistek RD, Dennis DA, Gabriel SM, Walker SA. Three-dimensional determination of femoral-tibial contact positions under in-vivo conditions using fluoroscopy. Clin. Biomech. 1998;13:455–472
  8. Zuffi S, Leardini A, Catani F, Fantozzi S, Cappello A. A model-based method for the reconstruction of total knee replacement kinematics. IEEE Trans. Med. Imag. 1999;18:981–991
  9. Haneishi H, Yagihashi Y, Miyake Y. A new method for distortion correction of electronic endoscope images. IEEE Trans. Med. Imag. 1995;14:548–555
  10. Weng J, Cohen P, Herniou M. Camera calibration with distortion models and accuracy evaluation. IEEE Trans. Pattern Anal. Machine Intell. 1992;14:965–980
  11. Kozinska D, Tretiak OJ, Nissanov J, Ozturk C. Multidimensional alignment using the Euclidean distance transform. Graphic Models Image Process. 1997;59:373–387
  12. Luenberger DG. Linear and nonlinear programming. Reading, MA: Addison Wesley; 1984.
  13. Grood ES, Suntay WJ. A joint coordinate system for the clinical description of three-dimensional motions: application to the knee. J. Biomech. Eng. 1983;15:136–144
  14. Schroeder W, Martin K, Lorensen B. The visualization toolkit: an object-oriented approach to 3-D graphics. Englewood Cliffs, NJ: Prentice-Hall; 1996.
  15. Cohen ZA, McCarthy DM, Kwak SD. Knee cartilage topography, thickness, and contact areas from MRI: in-vitro calibration and in-vivo measurements. Osteoarthritis Cart. 1999;7:95–109

PII: S0720-048X(03)00337-1

doi: 10.1016/j.ejrad.2003.09.018

European Journal of Radiology
Volume 53, Issue 1 , Pages 84-89 , January 2005