European Journal of Radiology
Volume 50, Issue 3 , Pages 285-291, June 2004

UK population dose from medical X-ray examinations

  • D. Hart

      Affiliations

    • Corresponding Author InformationCorresponding author. Tel.: +44-123-582-2647; fax: +44-123-583-3891.
  • ,
  • B.F. Wall

National Radiological Protection Board, Chilton, Didcot, Oxon OX11 0RQ, UK

Received 14 May 2003; received in revised form 10 June 2003; accepted 11 June 2003.

Abstract 

Objective: To assess the annual per caput and collective effective dose to the United Kingdom population from medical and dental X-ray examinations. Method: The results of a detailed survey of the frequency of X-ray examinations during the financial year 1997/1998 were combined with contemporary data on the effective doses typically received by patients. The resulting per caput and collective dose for 1997/1998 was updated to 2001/2002 by using annual statistics on the total numbers of computed tomography (CT), interventional and conventional examinations collected by the English Department of Health. Results: The annual per caput effective dose for the UK in 2001/2002 was estimated at 0.38 mSv. Over the last 10 years CT has more than doubled its contribution and is now responsible for 47% of the collective dose from medical X-rays. The contribution from conventional radiographic and fluoroscopic examinations has nearly halved to about 34%. Interventional and angiographic procedures together contribute the remaining 19%. Conclusions: The annual per caput effective dose of 0.38 mSv is low in comparison with other countries having similarly developed systems of health-care. This is due to both a lower frequency of X-ray examinations per head of population and generally lower doses in the UK than in other developed countries.

Keywords:  Collective dose, Effective dose, Computed tomography, X-ray examinations

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0720-048X(03)00178-5

doi:10.1016/S0720-048X(03)00178-5

European Journal of Radiology
Volume 50, Issue 3 , Pages 285-291, June 2004