European Journal of Radiology
Volume 44, Issue 3 , Pages 205-209, December 2002

Detection of simulated pulmonary nodules by single-exposure dual-energy computed radiography of the chest: effect of a computer-aided diagnosis system (Part 2)

  • Shoji Kido

      Affiliations

    • Department of Computer Science and Systems Engineering, Faculty of Engineering, Yamaguchi University, 16-1, Tokiwadai 2-Chome, Ube, Yamaguchi 755-8611, Japan
    • Corresponding Author InformationCorresponding author. Tel.: +81-836-85-9500; fax: +81-836-85-9501
  • ,
  • Keiko Kuriyama

      Affiliations

    • Department of Diagnostic Radiology, Osaka Medical Center For Cancer and Cardiovascular Diseases, 3-3, Nakamichi 1-Chome, Higashinari-Ku, Osaka, Osaka 537-8511, Japan
  • ,
  • Chikazumi Kuroda

      Affiliations

    • Department of Diagnostic Radiology, Osaka Medical Center For Cancer and Cardiovascular Diseases, 3-3, Nakamichi 1-Chome, Higashinari-Ku, Osaka, Osaka 537-8511, Japan
  • ,
  • Hironobu Nakamura

      Affiliations

    • Department of Radiology, Osaka University Medical School, 2-2 Yamada-Oka, Suita, Osaka 565-0871, Japan
  • ,
  • Wataru Ito

      Affiliations

    • Technology Development Center Miyanodai, Fuji Photo Film, 798 Kaisei-Cho, Asigarajyo-Gun, Kanagawa 258-0023, Japan
  • ,
  • Kazuo Shimura

      Affiliations

    • Technology Development Center Miyanodai, Fuji Photo Film, 798 Kaisei-Cho, Asigarajyo-Gun, Kanagawa 258-0023, Japan
  • ,
  • Hisatoyo Kato

      Affiliations

    • Technology Development Center Miyanodai, Fuji Photo Film, 798 Kaisei-Cho, Asigarajyo-Gun, Kanagawa 258-0023, Japan

Received 5 September 2002; received in revised form 6 September 2002; accepted 9 September 2002.

Abstract 

Objective: To evaluate the performance of the computer-aided diagnosis (CAD) scheme on the detection of pulmonary nodules (PNs) in single-exposure dual-energy subtraction computed radiography (CR) images of the chest, and to evaluate the effect of this CAD scheme on radiologists' detectabilities. Methods and material: We compared the detectability by the CAD scheme with the detectability by 12 observers by using conventional CR (C-CR) and bone-subtracted CR (BS-CR) images of 25 chest phantoms with a low-contrast nylon nodule. Results: Both in the CAD scheme and for the observers, the detectability of BS-CR images was superior to that of C-CR images (P<0.005). The detection performance of the CAD scheme was equal to that of the observers. The nodules detected by the CAD did not necessarily coincide with those by the observers. Thus, if observers can use the results of the CAD system as a ‘second opinion’, their detectabilities increase. Conclusion: The CAD system for detection of PNs in the single-exposure dual-energy subtraction method is promising for improving radiologists' detectabilities of PNs.

Keywords:  Dual-energy subtraction, Computed radiography, Computer-aided diagnosis (CAD), Pulmonary nodule

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0720-048X(02)00269-3

European Journal of Radiology
Volume 44, Issue 3 , Pages 205-209, December 2002