European Journal of Radiology
Volume 44, Issue 3 , Pages 198-204, December 2002

Computerized detection of pulmonary nodules by single-exposure dual-energy computed radiography of the chest (part 1)

  • Shoji Kido

      Affiliations

    • Department of Computer Science and Systems Engineering, Faculty of Engineering, Yamaguchi University, 16-1, Tokiwadai 2-Chome, Ube, Yamaguchi 755-8611, Japan
    • Corresponding Author InformationCorresponding author. Tel.: +81-836-85-9500; fax: +81-836-85-9501
  • ,
  • Hironobu Nakamura

      Affiliations

    • Department of Radiology, Osaka University Medical School, 2-2 Yamada-Oka, Suita, Osaka 565-0871, Japan
  • ,
  • Wataru Ito

      Affiliations

    • Technology Development Center Miyanodai, Fuji Photo Film, 798 Kaisei-Cho, Asigarajyo-Gun, Kanagawa 258-0023, Japan
  • ,
  • Kazuo Shimura

      Affiliations

    • Technology Development Center Miyanodai, Fuji Photo Film, 798 Kaisei-Cho, Asigarajyo-Gun, Kanagawa 258-0023, Japan
  • ,
  • Hisatoyo Kato

      Affiliations

    • Technology Development Center Miyanodai, Fuji Photo Film, 798 Kaisei-Cho, Asigarajyo-Gun, Kanagawa 258-0023, Japan

Received 5 September 2002; received in revised form 6 September 2002; accepted 9 September 2002.

Abstract 

Objective: To clarify the usefulness of computerized detection of pulmonary nodules (PNs) in single-exposure dual-energy subtraction computed radiography (CR) images of the chest. Methods and material: Our scheme uses bone-subtracted CR (BS-CR) images, and consists of a contrast-adaptive filter for detection of the candidates for PNs and a vessel-enhancing filter for elimination of vessel opacities in the candidates for PNs. For the evaluation, 12 clinical cases with multiple PNs were used, and four radiologists participated in this study. Results: The detectability of our computer-aided diagnosis (CAD) was compared with detectabilities of radiologists. The mean true-positive (TP) number of four radiologists was 1.60±1.03, and that of the CAD was 1.83±1.34. There was no significant difference in the nodule detectabilities between the radiologists and CAD (P=0.18). However, the false-positive (FP) rate of the CAD was 9.42±2.54 per image, whereas the mean FP rate of the radiologists was 1.40±0.64 per image. Conclusion: Computerized detection of PNs is considered to be useful in the determination of radiological diagnoses. However, reducing the number of FP findings remains an important problem to be solved.

Keywords:  Dual-energy subtraction, Computed radiography (CR), Computer-aided diagnosis (CAD), Pulmonary nodule

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0720-048X(02)00268-1

European Journal of Radiology
Volume 44, Issue 3 , Pages 198-204, December 2002