Unbiased estimation of the liver volume by the Cavalieri principle using magnetic resonance images

  • Bünyamin Sahin

      Affiliations

    • Department of Anatomy, Medical School, Ondokuz Mayis University, 55139 Samsun, Turkey
    • Corresponding Author InformationCorresponding author. Tel.: +90-362-457-6000x2262; fax: +90-362-457-6041
  • ,
  • Mehmet Emirzeoglu

      Affiliations

    • Department of Anatomy, Medical School, Ondokuz Mayis University, 55139 Samsun, Turkey
  • ,
  • Ahmet Uzun

      Affiliations

    • Department of Anatomy, Medical School, Ondokuz Mayis University, 55139 Samsun, Turkey
  • ,
  • Lütfi Incesu

      Affiliations

    • Department of Radiology, Medical School, Ondokuz Mayis University, 55139 Samsun, Turkey
  • ,
  • Yüksel Bek

      Affiliations

    • Department of Biostatistics, Medical School, Ondokuz Mayis University, 55139 Samsun, Turkey
  • ,
  • Sait Bilgic

      Affiliations

    • Department of Anatomy, Medical School, Ondokuz Mayis University, 55139 Samsun, Turkey
  • ,
  • Süleyman Kaplan

      Affiliations

    • Department of Histology and Embryology, Medical School, Ondokuz Mayis University, 55139 Samsun, Turkey

Received 19 February 2002; received in revised form 10 May 2002; accepted 13 May 2002.

Abstract 

Objective: It is often useful to know the exact volume of the liver, such as in monitoring the effects of a disease, treatment, dieting regime, training program or surgical application. Some non-invasive methodologies have been previously described which estimate the volume of the liver. However, these preliminary techniques need special software or skilled performers and they are not ideal for daily use in clinical practice. Here, we describe a simple, accurate and practical technique for estimating liver volume without changing the routine magnetic resonance imaging scanning procedure. Materials and methods: In this study, five normal livers, obtained from cadavers, were scanned by 0.5 T MR machine, in horizontal and sagittal planes. The consecutive sections, in 10 mm thickness, were used to estimate the whole volume of the liver by means of the Cavalieri principle. The volume estimations were done by three different performers to evaluate the reproducibility. Results: There are no statistical differences between the performers and real liver volumes (P>0.05). There is also high correlation between the estimates of performers and the real liver volume (r=0.993). Conclusion: We conclude that the combination of MR imaging with the Cavalieri principle is a non-invasive, direct and unbiased technique that can be safely applied to estimate liver volume with a very moderate workload per individual.

Keywords:  Cavalieri principle, Liver volume, MRI, Stereology

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0720-048X(02)00152-3

doi:10.1016/S0720-048X(02)00152-3

European Journal of Radiology
Volume 47, Issue 2 , Pages 164-170, August 2003